Mesajınızı Bırakın

           
  • Ev
  • Transformatör Yük Anahtarı Kademe Değiştirici Analizörü

Transformatör Yük Anahtarı Kademe Değiştirici Analizörü

Kısa Açıklama:

Item: RUN-OLTC01 Used for measuring the transition waveform, transition time, transient resistance three-phase synchronism of transformer on-load-tap changer. The tap-changer contacts are tested for electrical continuity during tap-changing. By applying a constant current while tapping, the tester looks for open circuit transients during tap-changing. Bouncing or High Resistance Contacts cause arcing and possible tap changer or transformer failure if left undetected. Used for measuring the transition waveform, transition time, transient resistance three-phase synchronism of transformer on-load-tap changer.
  • Run Test Electric Facebook logosu
  • Run Test Electric LinkedIn logosu

Ürün Detayı

Ürün Etiketleri

How to use this on-load tap-changer analyzer

Transformer on Load Tap Changer Test Equipment

The tap-changer contacts are tested for electrical continuity during tap-changing. By applying a constant current while tapping, the tester looks for open circuit transients during tap-changing. Bouncing or High Resistance Contacts cause arcing and possible tap changer or transformer failure if left undetected. Transformatör Yük Anahtarı Kademe Değiştirici Analizörü Transformatör Yük Anahtarı Kademe Değiştirici Analizörü

Parameters of the Transformer on-Load Tap Changer Analyzer

Öğe Parametre
Current Output 1.0A, 0.5A,0.2A
Menzil Transition resistance:0.3Ω~20Ω(1.0A) 5Ω~40Ω(0.5A) 20Ω~100Ω(0.2A) Transition time: 0~320ms
Open Circuit Voltage 24 V
Doğruluk Transition resistance:±(5% reading±0.1Ω) Transition time: ±(0.1%reading±0.2ms)
Sampling Rate 20 kHz
Depolama Internal storage
Çevre Operating temp.: -10℃~50℃
Bağıl Nem ≤85%, yoğuşmasız
Boyut 360*290*170 mm
Ağırlık Instrument Box: 6.15 KG Wire Box: 4.55 KG
Bizimkine bakın Yükte Kademe Değiştirici Test Cihazı Daha fazla bilgi için katalog Transformatör Yük Anahtarı Kademe Değiştirici Analizörü Transformatör Yük Anahtarı Kademe Değiştirici Analizörü

Picture of Kademe Değiştirici Test Cihazı

Features of on-Load Switch Tap-Changer Tester Test Set

1. Large Output Current, light weight 2. 7-inch high resolution LCD touchscreen, easy on-site operation. Good visibility even under strong light. 3. YN, Y, △ type transformer, display resistance value directly. 4. A complete protective circuit, good reliability. 5. The waveform display automatically adjusts the resistance, time value and amplitude according to the sampling value. 6. Internal data storage up to 500 sets. 7. Bluetooth and USB Port for data storage and PC communication. 8. Built-in thermo-printer.

Why choose us?

1.After-sale Service: 100% quality guaranteed. 2.One year warranty from the date of purchase, customers enjoy a free repair or replacement service. 3.Lifetime maintenance and free remotely technical support. Servis: The instrument will be repaired and replaced free of charge for product quality problems within one year from the date of purchase, and will provide lifetime warranty and technical services. If you find any abnormalities or malfunctions in the instrument, please contact the company in time to arrange the most convenient solution for you.
 

Mesajınızı Bırakın