  • Penguji resistansi isolasi tegangan tinggi 5kv

Penguji resistansi isolasi tegangan tinggi 5kv

Deskripsi Singkat:

ITEM: RUN-IR526 ● 5 ranges: 250V, 500V, 1000V, 2500V, 5000V the maximum test can reach 10TΩ. ● Safety Standard IEC 61010-1    CAT.IV  600V Pollution Degree 2 IEC 61326      EMC specification: test, control and electrical equipment for testing IEC60529 IP64 (Outer closed state) ● Service  The instrument will be repaired and replaced free of charge for product quality problems within one year from the date of purchase, and will provide lifetime warranty and technical services. If you find any abnormalities or malfunctions in the instrument, please contact the company in time to arrange the most convenient solution for you.
  • Menjalankan logo Facebook Uji Coba Listrik
  • Menjalankan logo LinkedIn Run Test Electric

Detail Produk

Label Produk

Penguji resistansi isolasi tegangan tinggi 5kv



Safety Standard 5 ranges: 250V, 500V, 1000V, 2500V, 5000V the maximum test can reach 10TΩ. IEC 61010-1    CAT.IV  600V Pollution Degree 2 IEC 61326      EMC specification: test, control and electrical equipment for testing IEC60529 IP64 (Outer closed state)  


Technical Parameter of the 5kv penguji ketahanan isolasi:


Daya AC220V±10%,50/60 HZ ,20 VA
Baterai16.8V Lithium ion rechargeable battery
Daya Tahan Baterai5000V@100M, 6 hours
Dimensi (P x L x T)27cm x 23cm x 16cm
● Weight3,8 kg
Uji akurasi tegangan:the nominal value  100% to 110%
● Output Voltage Monitoring accuracy± 5% ± 10V
● Voltage test rangeAC:30-600V(50HZ/60HZ), DC:30-600V
● Voltage test precision±2%±3dgt
Kisaran pengujian saat ini10mA
Ketepatan pengukuran saat ini5% + 0.2nA
Arus hubung singkat 2-5 mA, adjustable
● Capacitance Test Range25uF
● Capacitance Test Accuracy10%+0.03uF
Laju pengosongan kapasitor from 5000V to 10V,1S/µF
Perlindungan2% error, shielding 500K Ω leakage resistance under 100m Ω load
● Analog Display Range100kΩ to 10TΩ
● Digital Display Range10K Ω to 10TΩ
● Insulation Alarm0.01M Ω to 9999.99m Ω
● Insulation resistance testing range and accuracy(T:23±5ºC ,RH :45 – 75%)


Introduction of the resistance test equipment resistance meter:


 



Main features for the 5kv insulation resistance meter


● Insulation resistance range 10TΩ@5kV 
● The short-circuit current can be adjusted up to 5mA. 
● Automatically display the test values of polarization index (PI), Dielectric absorption ratio (DAR), Dielectric Discharge(DD), Step Voltage(SV) and can test leakage current and capacitance. 
Performa anti-interferensi yang sangat baik, ketika arus interferensi mencapai 2mA, instrumen masih menjamin akurasi pengujian. 
● Identify AC or DC automatically. 
Produk uji kapasitif habis dengan cepat. Ketika kabel diuji, pelepasan secara manual tidak diperlukan, dan instrumen secara otomatis melepaskan dengan cepat. 
● 2 power modes: use lithium battery for power supply, battery life can reach 6 hours. At the same time, it can be charged in use. In the event of a power failure, it can automatically switch from AC power supply to battery power supply. 
● Simple use, display insulation resistance analog column. 
Fungsi pemfilteran digital, nilai tampilan deviasi pengaruh eksternal yang menyebabkan titik mitigasi menggunakan fungsi filter. 
● Perfect protection function, the G/E circuit has a built-in fuse and a burnout prompt. When it burns out, there will be a red background and white text prompt on the screen. 
● Data storage


Dangerous ( Improper operation can lead to serious or fatal damage)


● Please wear insulated gloves before use. 
● Do not measure in a circuit above AC/DC600V. 
● Do not test in flammable places, sparks may cause an explosion. 
● Do not operate when the surface of the instrument is wet or the operator's hands are wet. 
● Please do not connect the test lead with power. 
● Do not touch the circuit under test immediately during or after the test, as it may cause electric shock. 
● Please stop the test when any dirt or charcoal that easily damages the insulation characteristics is found on the test line or terminal.


Notice (Improper operation may cause personal injury or damage to the instrument)


1. Before measuring, confirm that the voltage is selected at an appropriate value. 
2. If the battery is not used for a long time, the battery should be fully charged and stored, and refilled within three months. 
3. Do not place it for a long time in a place with high temperature, humidity, condensation possibility and direct sunlight. 
4. Please use a damp cloth or detergent to clean the case of the instrument, do not use abrasives or solvents. 
5. When the instrument is wet, please dry it before storing.