{"id":244,"date":"2025-02-24T05:42:42","date_gmt":"2025-02-24T05:42:42","guid":{"rendered":"http:\/\/43.135.160.122\/?p=244"},"modified":"2025-04-24T02:16:05","modified_gmt":"2025-04-24T02:16:05","slug":"what-is-transformer-bdv-test","status":"publish","type":"post","link":"https:\/\/www.voltage-tester.com\/id\/what-is-transformer-bdv-test-article\/","title":{"rendered":"Apa itu uji BDV transformator"},"content":{"rendered":"<p><strong>Apa yang dimaksud dengan penguji BDV transformator?<\/strong><\/p>\n\n\n\n<p><strong>Tes BDV<\/strong>&nbsp;berarti&nbsp;<strong>Uji Tegangan Rusak<\/strong>. Tes ini dilakukan untuk memverifikasi kekuatan dielektrik minyak transformator. Kekuatan Dielektrik adalah kapasitas maksimum untuk menahan tegangan minyak isolasi.<\/p>\n\n\n\n<p>Analisis variasi nilai tegangan tembus dalam pengujian Ketika tegangan tembus minyak transformator diuji, umumnya secangkir minyak diuji 5 kali, dan nilai rata-rata diambil.<\/p>\n\n\n\n<p><strong>Bagaimana cara kerja penguji BDV oli?<\/strong><\/p>\n\n\n\n<p>Pengoperasian normal seharusnya: setelah oli uji penuh, diamkan selama 10 menit dan kemudian lakukan uji kenaikan. Setelah setiap kerusakan, gunakan batang kaca bersih yang sudah disiapkan untuk membuat beberapa kali di antara elektroda atau dengan lembut menggetarkan cangkir minyak untuk mencapai kerusakan. Jembatan yang baru terbentuk di antara elektroda dapat dibiarkan selama 5 menit untuk pengujian berikutnya.<\/p>\n\n\n\n<p><strong>Perhatikan saat menggunakan penguji tegangan tembus oli:<\/strong><\/p>\n\n\n\n<p>Pertama kali tegangan tembus sangat rendah: tes pertama mungkin memiliki beberapa faktor eksternal yang disebabkan oleh injeksi oli ke dalam cangkir oli atau permukaan elektroda cangkir oli sebelum injeksi oli, sehingga nilai pertama rendah, sehingga perlu dilakukan tes keenam dan mengambil rata-rata 2 hingga 6 kali.<\/p>\n\n\n\n<p>Ini&nbsp;<strong>penguji bdv minyak transformator<\/strong>&nbsp;memenuhi beberapa standar, pilih standar yang sesuai dan diperlukan untuk pengujian.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"http:\/\/43.135.160.122\/wp-content\/uploads\/2025\/02\/517f4300.webp\" alt=\"Apa itu uji BDV transformator\" class=\"wp-image-246\" srcset=\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/517f4300.webp 1024w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/517f4300-300x169.webp 300w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/517f4300-768x432.webp 768w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/517f4300-18x10.webp 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"http:\/\/43.135.160.122\/wp-content\/uploads\/2025\/02\/5c3c09a9.webp\" alt=\"Apa itu uji BDV transformator\" class=\"wp-image-245\" srcset=\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/5c3c09a9.webp 1024w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/5c3c09a9-300x169.webp 300w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/5c3c09a9-768x432.webp 768w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/5c3c09a9-18x10.webp 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>What is the transformer BDV tester? BDV test&nbsp;means the&nbsp;Breakdown Voltage Test. This test is performed for verifying the dielectric strength of the oil of the transformer. Dielectric Strength is the maximum capacity to resist the voltage of insulating oil. Analysis of the variation of breakdown voltage value in the test When the breakdown voltage of [&hellip;]<\/p>","protected":false},"author":1,"featured_media":247,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[772],"tags":[],"class_list":["post-244","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What is transformer BDV test - Run Test<\/title>\n<meta name=\"description\" content=\"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.voltage-tester.com\/id\/what-is-transformer-bdv-test-article\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is transformer BDV test - Run Test\" \/>\n<meta property=\"og:description\" content=\"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.voltage-tester.com\/id\/what-is-transformer-bdv-test-article\/\" \/>\n<meta property=\"og:site_name\" content=\"Run Test Electric Manufacturing Co., Ltd.\" \/>\n<meta property=\"article:published_time\" content=\"2025-02-24T05:42:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-24T02:16:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"768\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"user\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"user\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/\"},\"author\":{\"name\":\"user\",\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/person\/3ff7cf5be00ac7d8c39620fae1847a3c\"},\"headline\":\"What is transformer BDV test\",\"datePublished\":\"2025-02-24T05:42:42+00:00\",\"dateModified\":\"2025-04-24T02:16:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/\"},\"wordCount\":248,\"publisher\":{\"@id\":\"https:\/\/www.voltage-tester.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp\",\"articleSection\":[\"Industry News\"],\"inLanguage\":\"id\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/\",\"url\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/\",\"name\":\"What is transformer BDV test - Run Test\",\"isPartOf\":{\"@id\":\"https:\/\/www.voltage-tester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp\",\"datePublished\":\"2025-02-24T05:42:42+00:00\",\"dateModified\":\"2025-04-24T02:16:05+00:00\",\"description\":\"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#primaryimage\",\"url\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp\",\"contentUrl\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp\",\"width\":768,\"height\":768,\"caption\":\"640-19 test\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.voltage-tester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is transformer BDV test\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.voltage-tester.com\/#website\",\"url\":\"https:\/\/www.voltage-tester.com\/\",\"name\":\"Run Test Electric Manufacturing Co., Ltd.\",\"description\":\"Run Test Electric Manufacturing Co., Ltd.\",\"publisher\":{\"@id\":\"https:\/\/www.voltage-tester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.voltage-tester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.voltage-tester.com\/#organization\",\"name\":\"Run Test Electric Manufacturing Co., Ltd.\",\"url\":\"https:\/\/www.voltage-tester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/cropped-logo-2-1.png\",\"contentUrl\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/cropped-logo-2-1.png\",\"width\":264,\"height\":50,\"caption\":\"Run Test Electric Manufacturing Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/person\/3ff7cf5be00ac7d8c39620fae1847a3c\",\"name\":\"user\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g\",\"caption\":\"user\"},\"sameAs\":[\"http:\/\/43.135.160.122\"],\"url\":\"https:\/\/www.voltage-tester.com\/id\/author\/user\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is transformer BDV test - Run Test","description":"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.voltage-tester.com\/id\/what-is-transformer-bdv-test-article\/","og_locale":"id_ID","og_type":"article","og_title":"What is transformer BDV test - Run Test","og_description":"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.","og_url":"https:\/\/www.voltage-tester.com\/id\/what-is-transformer-bdv-test-article\/","og_site_name":"Run Test Electric Manufacturing Co., Ltd.","article_published_time":"2025-02-24T05:42:42+00:00","article_modified_time":"2025-04-24T02:16:05+00:00","og_image":[{"width":768,"height":768,"url":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp","type":"image\/webp"}],"author":"user","twitter_card":"summary_large_image","twitter_misc":{"Written by":"user","Est. reading time":"2 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#article","isPartOf":{"@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/"},"author":{"name":"user","@id":"https:\/\/www.voltage-tester.com\/#\/schema\/person\/3ff7cf5be00ac7d8c39620fae1847a3c"},"headline":"What is transformer BDV test","datePublished":"2025-02-24T05:42:42+00:00","dateModified":"2025-04-24T02:16:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/"},"wordCount":248,"publisher":{"@id":"https:\/\/www.voltage-tester.com\/#organization"},"image":{"@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#primaryimage"},"thumbnailUrl":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp","articleSection":["Industry News"],"inLanguage":"id"},{"@type":"WebPage","@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/","url":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/","name":"What is transformer BDV test - Run Test","isPartOf":{"@id":"https:\/\/www.voltage-tester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#primaryimage"},"image":{"@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#primaryimage"},"thumbnailUrl":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp","datePublished":"2025-02-24T05:42:42+00:00","dateModified":"2025-04-24T02:16:05+00:00","description":"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.","breadcrumb":{"@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#primaryimage","url":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp","contentUrl":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/640-19-1.webp","width":768,"height":768,"caption":"640-19 test"},{"@type":"BreadcrumbList","@id":"https:\/\/www.voltage-tester.com\/what-is-transformer-bdv-test-article\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.voltage-tester.com\/"},{"@type":"ListItem","position":2,"name":"What is transformer BDV test"}]},{"@type":"WebSite","@id":"https:\/\/www.voltage-tester.com\/#website","url":"https:\/\/www.voltage-tester.com\/","name":"Run Test Electric Manufacturing Co., Ltd.","description":"Run Test Electric Manufacturing Co., Ltd.","publisher":{"@id":"https:\/\/www.voltage-tester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.voltage-tester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/www.voltage-tester.com\/#organization","name":"Run Test Electric Manufacturing Co., Ltd.","url":"https:\/\/www.voltage-tester.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.voltage-tester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/cropped-logo-2-1.png","contentUrl":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/cropped-logo-2-1.png","width":264,"height":50,"caption":"Run Test Electric Manufacturing Co., Ltd."},"image":{"@id":"https:\/\/www.voltage-tester.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.voltage-tester.com\/#\/schema\/person\/3ff7cf5be00ac7d8c39620fae1847a3c","name":"user","image":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.voltage-tester.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g","caption":"user"},"sameAs":["http:\/\/43.135.160.122"],"url":"https:\/\/www.voltage-tester.com\/id\/author\/user\/"}]}},"_links":{"self":[{"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/posts\/244","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/comments?post=244"}],"version-history":[{"count":0,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/posts\/244\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/media\/247"}],"wp:attachment":[{"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/media?parent=244"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/categories?post=244"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/tags?post=244"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}