{"id":135,"date":"2024-11-26T06:55:00","date_gmt":"2024-11-26T06:55:00","guid":{"rendered":"http:\/\/43.135.160.122\/?p=135"},"modified":"2025-04-24T02:16:06","modified_gmt":"2025-04-24T02:16:06","slug":"expertise-about-the-transformer-tan-delta-tester","status":"publish","type":"post","link":"https:\/\/www.voltage-tester.com\/id\/expertise-about-the-transformer-tan-delta-tester-article\/","title":{"rendered":"Expertise about the transformer tan delta tester"},"content":{"rendered":"<p>A transformer&nbsp;<strong>tan delta tester<\/strong>&nbsp;is a diagnostic tool used to measure the&nbsp;<strong>dissipation factor (tan \u03b4)<\/strong>&nbsp;or&nbsp;<strong>loss tangent<\/strong>&nbsp;of the insulation in transformers, which is a key indicator of the condition of the transformer\u2019s dielectric insulation.<\/p>\n\n\n\n<p><strong>Key Concepts:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Tan Delta (Tan \u03b4):<\/strong>\u00a0This is the ratio of the resistive (loss) component of the insulation current to the capacitive (reactive) component of the insulation current. A high tan delta value indicates that the insulation is degrading or that there is a problem, such as contamination, moisture ingress, or aging. In essence, tan delta is an indicator of how much energy is being lost as heat in the insulating material.<\/li>\n\n\n\n<li><strong>Dielectric Loss:<\/strong>\u00a0In an ideal transformer, the dielectric material (e.g., oil, solid insulation like paper, etc.) should not dissipate significant energy. However, as insulation ages or deteriorates, it becomes less efficient at blocking electrical currents, and this leads to energy losses, which can be measured as the\u00a0<strong>tan delta<\/strong>.<\/li>\n<\/ul>\n\n\n\n<p><strong>Purpose of the Tan Delta Test:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Condition Monitoring:<\/strong>\u00a0Regular tan delta testing helps track the aging of insulation over time, ensuring that transformers are functioning safely and efficiently.<\/li>\n\n\n\n<li><strong>Preventive Maintenance:<\/strong>\u00a0Detects insulation degradation before it leads to failure, allowing for timely maintenance or replacement of components.<\/li>\n\n\n\n<li><strong>Diagnostic Tool:<\/strong>\u00a0Can help identify specific problems like moisture, contamination, or partial discharge activity within the transformer\u2019s insulation.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">In what occassion we use the transformer tan delta tester to test<\/h3>\n\n\n\n<p>The&nbsp;<strong>transformer tan delta tester<\/strong>&nbsp;is typically used in the following occasions to test the condition of transformer insulation and diagnose potential problems. Each of these scenarios is aimed at assessing the health of the transformer\u2019s dielectric materials, such as oil, paper, or the combination of both, to ensure the transformer is operating efficiently and safely.<\/p>\n\n\n\n<p>1. Routine Maintenance Testing<\/p>\n\n\n\n<p>2. Commissioning or Acceptance Testing<\/p>\n\n\n\n<p>3. After Transformer Repairs or Refurbishment<\/p>\n\n\n\n<p>4. During Transformer Oil Testing (Oil Contamination or Degradation)<\/p>\n\n\n\n<p>5. Troubleshooting or Diagnostic Testing (Suspected Faults)<\/p>\n\n\n\n<p>6. End-of-Life Assessment (Aging Transformers)<\/p>\n\n\n\n<p>7. Transformer Condition Monitoring (Online Monitoring)<\/p>\n\n\n\n<p>8. After Severe Electrical or Mechanical Events<\/p>\n\n\n\n<p>9. High Voltage Testing for Operational Load Tests<\/p>\n\n\n\n<p><strong>The transformer tan delta test is commonly used to assess the health of transformer insulation during routine maintenance, after repairs or installation, when troubleshooting issues, or when a transformer is aging or near the end of its service life. It&#8217;s an essential tool for identifying insulation degradation or other dielectric issues that could lead to transformer failure.<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Equipment Show about the tan delta tester<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"768\" src=\"http:\/\/43.135.160.122\/wp-content\/uploads\/2025\/02\/1122.webp\" alt=\"\" class=\"wp-image-139\" srcset=\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1122.webp 768w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1122-300x300.webp 300w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1122-150x150.webp 150w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1122-12x12.webp 12w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"719\" src=\"http:\/\/43.135.160.122\/wp-content\/uploads\/2025\/02\/179.webp\" alt=\"\" class=\"wp-image-136\" srcset=\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/179.webp 1024w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/179-300x211.webp 300w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/179-768x539.webp 768w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/179-18x12.webp 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"629\" src=\"http:\/\/43.135.160.122\/wp-content\/uploads\/2025\/02\/206.webp\" alt=\"\" class=\"wp-image-138\" srcset=\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/206.webp 1024w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/206-300x184.webp 300w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/206-768x472.webp 768w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/206-18x12.webp 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"581\" src=\"http:\/\/43.135.160.122\/wp-content\/uploads\/2025\/02\/186.webp\" alt=\"\" class=\"wp-image-137\" srcset=\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/186.webp 1024w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/186-300x170.webp 300w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/186-768x436.webp 768w, https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/186-18x10.webp 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Service Of RUN TEST ELECTRIC<\/h3>\n\n\n\n<p><strong>The instrument will be repaired and replaced free of charge for product quality problems within one year from the date of purchase, and will provide lifetime warranty and&nbsp;<\/strong><strong>technical&nbsp;services. If you find any abnormalities or malfunctions in the instrument, please contact the company in time to arrange the most convenient solution for you.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>A transformer&nbsp;tan delta tester&nbsp;is a diagnostic tool used to measure the&nbsp;dissipation factor (tan \u03b4)&nbsp;or&nbsp;loss tangent&nbsp;of the insulation in transformers, which is a key indicator of the condition of the transformer\u2019s dielectric insulation. Key Concepts: Purpose of the Tan Delta Test: In what occassion we use the transformer tan delta tester to test The&nbsp;transformer tan delta [&hellip;]<\/p>","protected":false},"author":1,"featured_media":140,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[772],"tags":[],"class_list":["post-135","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Expertise about the transformer tan delta tester - Run Test Electric Manufacturing Co., Ltd.<\/title>\n<meta name=\"description\" content=\"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.voltage-tester.com\/id\/expertise-about-the-transformer-tan-delta-tester-article\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Expertise about the transformer tan delta tester - Run Test Electric Manufacturing Co., Ltd.\" \/>\n<meta property=\"og:description\" content=\"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.voltage-tester.com\/id\/expertise-about-the-transformer-tan-delta-tester-article\/\" \/>\n<meta property=\"og:site_name\" content=\"Run Test Electric Manufacturing Co., Ltd.\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-26T06:55:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-24T02:16:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"user\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"user\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/\"},\"author\":{\"name\":\"user\",\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/person\/3ff7cf5be00ac7d8c39620fae1847a3c\"},\"headline\":\"Expertise about the transformer tan delta tester\",\"datePublished\":\"2024-11-26T06:55:00+00:00\",\"dateModified\":\"2025-04-24T02:16:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/\"},\"wordCount\":481,\"publisher\":{\"@id\":\"https:\/\/www.voltage-tester.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp\",\"articleSection\":[\"Industry News\"],\"inLanguage\":\"id\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/\",\"url\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/\",\"name\":\"Expertise about the transformer tan delta tester - Run Test Electric Manufacturing Co., Ltd.\",\"isPartOf\":{\"@id\":\"https:\/\/www.voltage-tester.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp\",\"datePublished\":\"2024-11-26T06:55:00+00:00\",\"dateModified\":\"2025-04-24T02:16:06+00:00\",\"description\":\"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#primaryimage\",\"url\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp\",\"contentUrl\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp\",\"width\":1024,\"height\":768,\"caption\":\"Expertise about the transformer tan delta tester\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.voltage-tester.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Expertise about the transformer tan delta tester\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.voltage-tester.com\/#website\",\"url\":\"https:\/\/www.voltage-tester.com\/\",\"name\":\"Run Test Electric Manufacturing Co., Ltd.\",\"description\":\"Run Test Electric Manufacturing Co., Ltd.\",\"publisher\":{\"@id\":\"https:\/\/www.voltage-tester.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.voltage-tester.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.voltage-tester.com\/#organization\",\"name\":\"Run Test Electric Manufacturing Co., Ltd.\",\"url\":\"https:\/\/www.voltage-tester.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/cropped-logo-2-1.png\",\"contentUrl\":\"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/cropped-logo-2-1.png\",\"width\":264,\"height\":50,\"caption\":\"Run Test Electric Manufacturing Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/person\/3ff7cf5be00ac7d8c39620fae1847a3c\",\"name\":\"user\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.voltage-tester.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g\",\"caption\":\"user\"},\"sameAs\":[\"http:\/\/43.135.160.122\"],\"url\":\"https:\/\/www.voltage-tester.com\/id\/author\/user\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Expertise about the transformer tan delta tester - Run Test Electric Manufacturing Co., Ltd.","description":"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.voltage-tester.com\/id\/expertise-about-the-transformer-tan-delta-tester-article\/","og_locale":"id_ID","og_type":"article","og_title":"Expertise about the transformer tan delta tester - Run Test Electric Manufacturing Co., Ltd.","og_description":"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.","og_url":"https:\/\/www.voltage-tester.com\/id\/expertise-about-the-transformer-tan-delta-tester-article\/","og_site_name":"Run Test Electric Manufacturing Co., Ltd.","article_published_time":"2024-11-26T06:55:00+00:00","article_modified_time":"2025-04-24T02:16:06+00:00","og_image":[{"width":1024,"height":768,"url":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp","type":"image\/webp"}],"author":"user","twitter_card":"summary_large_image","twitter_misc":{"Written by":"user","Est. reading time":"4 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#article","isPartOf":{"@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/"},"author":{"name":"user","@id":"https:\/\/www.voltage-tester.com\/#\/schema\/person\/3ff7cf5be00ac7d8c39620fae1847a3c"},"headline":"Expertise about the transformer tan delta tester","datePublished":"2024-11-26T06:55:00+00:00","dateModified":"2025-04-24T02:16:06+00:00","mainEntityOfPage":{"@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/"},"wordCount":481,"publisher":{"@id":"https:\/\/www.voltage-tester.com\/#organization"},"image":{"@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#primaryimage"},"thumbnailUrl":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp","articleSection":["Industry News"],"inLanguage":"id"},{"@type":"WebPage","@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/","url":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/","name":"Expertise about the transformer tan delta tester - Run Test Electric Manufacturing Co., Ltd.","isPartOf":{"@id":"https:\/\/www.voltage-tester.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#primaryimage"},"image":{"@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#primaryimage"},"thumbnailUrl":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp","datePublished":"2024-11-26T06:55:00+00:00","dateModified":"2025-04-24T02:16:06+00:00","description":"China transformer test supplier, we provide Relay Protection Test, Resistance test, Circuit Breaker Test, and Partial Discharge Test for you with good price.","breadcrumb":{"@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#primaryimage","url":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp","contentUrl":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/1222.webp","width":1024,"height":768,"caption":"Expertise about the transformer tan delta tester"},{"@type":"BreadcrumbList","@id":"https:\/\/www.voltage-tester.com\/expertise-about-the-transformer-tan-delta-tester-article\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.voltage-tester.com\/"},{"@type":"ListItem","position":2,"name":"Expertise about the transformer tan delta tester"}]},{"@type":"WebSite","@id":"https:\/\/www.voltage-tester.com\/#website","url":"https:\/\/www.voltage-tester.com\/","name":"Run Test Electric Manufacturing Co., Ltd.","description":"Run Test Electric Manufacturing Co., Ltd.","publisher":{"@id":"https:\/\/www.voltage-tester.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.voltage-tester.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/www.voltage-tester.com\/#organization","name":"Run Test Electric Manufacturing Co., Ltd.","url":"https:\/\/www.voltage-tester.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.voltage-tester.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/cropped-logo-2-1.png","contentUrl":"https:\/\/www.voltage-tester.com\/wp-content\/uploads\/2025\/02\/cropped-logo-2-1.png","width":264,"height":50,"caption":"Run Test Electric Manufacturing Co., Ltd."},"image":{"@id":"https:\/\/www.voltage-tester.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.voltage-tester.com\/#\/schema\/person\/3ff7cf5be00ac7d8c39620fae1847a3c","name":"user","image":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.voltage-tester.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g","caption":"user"},"sameAs":["http:\/\/43.135.160.122"],"url":"https:\/\/www.voltage-tester.com\/id\/author\/user\/"}]}},"_links":{"self":[{"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/posts\/135","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/comments?post=135"}],"version-history":[{"count":0,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/posts\/135\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/media\/140"}],"wp:attachment":[{"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/media?parent=135"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/categories?post=135"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.voltage-tester.com\/id\/wp-json\/wp\/v2\/tags?post=135"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}